top of page
Entretien Pro-Actif logo

Your periodic home maintenance

Learn more about our maintenance program for your home equipment.

Plumbing

Descaling shower heads

Quarterly

Descaling to ensure longevity and proper functioning

Plumbing

Check for any leaks

Quarterly

For optimal proactive maintenance, we recommend:
Quarterly visual inspection.
Annual audit.

Plumbing

Clean the aerators on the taps

Quarterly

Light cleaning every 3 months
Thorough cleaning once a year

Plumbing

Partial draining of the water heater to remove sediment

Yearly

Light drain: every six months, for areas with very hard water
Complete or partial drain: once a year, ideally before the peak usage season (spring or fall)

Plumbing

Drain inspection and cleaning

Quarterly

Monthly visual inspection: regularly check that water is flowing without any noticeable slowdown.
Preventive cleaning twice a year: twice a year, carry out a thorough cleaning to remove grease and residue.

Openings

Cleaning window sills

Quarterly to yearly

Light quarterly cleaning: remove visible debris (leaves, dust) with a soft cloth or a vacuum cleaner fitted with a brush attachment.
Bi-annual deep cleaning: twice a year, perform a more thorough cleaning that includes the frame, track, sill, and window gutters.
Annual professional inspection: an Entretien Pro-Actif technician inspects the condition of the seals, the integrity of the fasteners, and proper water drainage.

Openings

Checking the tightness of windows

Quarterly to yearly

Six-monthly self-inspection: visually check the condition of the seals and look for signs of wear or discoloration every six months.
Annual professional audit: an Entretien Pro-Actif technician carries out a detailed inspection (smoke test, checking seals and counter-profiles) and provides you with a full report.

Openings

Lubrication of window mechanisms

Quarterly to annual

Graissage léger : tous les six mois, surtout avant les saisons extrêmes (printemps et automne).
Graissage complet : une fois par an, lors de l’entretien professionnel annuel, pour un lubrifiant adapté à chaque type de mécanisme.

Exterior doors

Checking seals and draftstops, locks, and hinges

1-2 times a year

Six-monthly inspection: visually check the condition of the seals and weatherstripping, test the locks and ensure that the hinges are not noisy or loose, every six months.
Annual professional maintenance: an Entretien Pro-Actif technician carries out a thorough inspection and adjusts, replaces or lubricates any defective parts.

Portes extérieures

Lubrification des pentures des portes extérieures

1-2 fois par an

Light lubrication: twice a year, ideally before cold and wet seasons.
Professional maintenance: once a year, during the annual Entretien Pro-Actif visit, for a complete check-up and application of a high-performance lubricant.

Interior doors

Lubrication of interior door hinges

Once or twice a year

Entretien léger: tous les six mois, pour un coup de spray lubrifiant rapide et efficace.
Entretien approfondi: und fois par an, lors de votre visite annuelle Entretien Pro-Actif, pour un contrôle complet et l’application d’une graisse ou d’un lubrifiant adapté aux charnières intérieures.

Interior doors

Minor adjustments

Twice a year

Six-monthly check: twice a year, check that each door is properly aligned with its frame and does not rub against the floor or the strike plate.
Annual professional maintenance: during the annual Entretien Pro-Actif visit, a technician will make any necessary fine adjustments and check the general condition of the door and its fittings.

Electricity

GFCI outlet testing

Bimonthly

Monthly or bi-monthly test
Annual professional inspection

Électricité

Nettoyage de l'éclairage DEL ou halogène

1-2 fois par an

Toutes les 6 mois pour les luminaires intérieurs exposés à la poussière (salons, chambres, bureaux)
Tous les 3 mois pour les luminaires de cuisine ou de salle de bain, soumis à la vapeur et aux projections
Entretien professionnel annuel par un technicien Entretien Pro-Actif pour un nettoyage complet et un contrôle des connexions électriques

Heating & Ventilation

Cleaning the filters of the heat pump/wall-mounted air conditioner

1 to 2 months

Monthly cleaning: in a normal environment, remove and rinse the filters once a month.
Bi-monthly cleaning: if you live with pets, smoke indoors, or your environment is very dusty, increase the frequency to every two weeks.
Annual professional maintenance: an Entretien Pro-Actif technician performs a complete cleaning.

Heating & Ventilation

Cleaning furnace filters

1 to 3 months

Appartements et maisons peu poussiéreux: nettoyage ou remplacement tous les trois mois
Environnements à forte poussière ou animaux: nettoyage ou remplacement tous les mois
Inspection professionnelle annuelle: un technicien Entretien Pro-Actif vérifie le reste de l’installation (thermostat, échangeur de chaleur, conduits) lors de sa visite annuelle

Heating & Ventilation

Cleaning the air exchanger filters

1 to 2 months

Monthly cleaning: In a standard residential environment, remove and dust the filters at least once a month.
Bi-monthly cleaning: if you live with pets or in a very dusty area, clean the filters every two weeks.
Annual replacement or as recommended: some high-efficiency filters must be replaced once a year or as recommended by the manufacturer.

Heating & Ventilation

Cleaning the fans systems

Monthly to quarterly

Light cleaning: once a month in high-use rooms (kitchen, bathroom).
Deep cleaning: every three months in other rooms (living room, bedrooms).
Professional maintenance: once a year, for a complete inspection and repair by an Entretien Pro-Actif technician.

Heating & Ventilation

Cleaning and dusting the external plate and bathroom fan

2 to 3 months

Dépoussiérage léger: tous les deux mois, pour enlever la poussière superficielle de la grille et de l’hélice.
Nettoyage approfondi: deux fois par an, idéalement avant l’été et avant l’hiver, pour démonter, laver et sécher entièrement la plaque et les pales du ventilateur.
Entretien professionnel annuel: un technicien Entretien Pro-Actif intervient pour un nettoyage complet, un contrôle du moteur et une lubrification si nécessaire.

Heating & Ventilation

Thermostat maintenance

Annual

Remplacement des piles: une fois par an, même si le voyant « piles faibles » n’est pas allumé.
Vérification et recalibration: tous les deux ans, pour ajuster la sonde de température si nécessaire.
Nettoyage et dépoussiérage: une fois par an, juste avant la saison de chauffe ou de climatisation.
Inspection des connexions: lors de chaque visite annuelle de votre système de chauffage/climatisation, pour vérifier qu’aucun fil n’est desserré ou corrodé.

Household appliances

Cleaning the refrigerator: coils, door seals, drip tray

3 to 6 months

Coils (rear or underside): every six months, ideally during each major spring and fall cleaning.
Door seals: every three months, to prevent clogging and detect signs of wear or deterioration.
Drip tray: every six months, at the same time as cleaning the coils.

Household appliances

Cleaning the dryer

1 to 2 months

Après chaque cycle de séchage: à la fin de chaque utilisation, retirez et dépoussiérez le filtre pour éliminer immédiatement les accumulations.
Chaque mois : dépoussiérage du filtre à charpie (peluches, fibres).
Tous les six mois : nettoyage du tambour et des joints d’étanchéité.
Une fois par an : inspection et nettoyage professionnel du conduit d’évacuation (intérieur du mur), du boîtier moteur et des résistances.

Household appliances

Cleaning the dryer vents

1 to 2 times per year

Semi-annual cleaning: every six months, especially if you use the dryer frequently or have long-haired pets.
Annual professional inspection: an Entretien Pro-Actif technician performs a thorough cleaning of the built-in duct and checks the condition of the seals and connections.

Household appliances

Descaling and cleaning of washing machine seals, detergent drawer, inspection of pipes and connections

1 to 3 months

Every three months: light descaling of joints and quick cleaning of the detergent drawer.
Every six months: visual inspection of pipes, checking of clamps, and replacement of flexible hoses if necessary.
Annually: professional Entretien Pro-Actif service for complete descaling (specialized product), connection check, and pressure test.

Household appliances

Cleaning the dishwasher: cleaning the filter, checking the spray arms, cleaning cycle

1 to 3 months

Nettoyage du filtre: toutes les 4 à 6 semaines
Vérification des bras gicleurs: en même temps que le filtre, soit 4 à 6 fois par an
Cycle de nettoyage complet: tous les 3 à 6 mois, selon l’usage et la dureté de l’eau

Household appliances

Cleaning kitchen hood filters

Quarterly

Nettoyage léger: toutes les 4 à 6 semaines, en fonction de votre usage (plus fréquent si vous cuisinez souvent à haute température ou avec des fritures).
Nettoyage approfondi: tous les trois mois, pour un entretien plus complet des filtres métalliques ou à charbon.
Entretien professionnel annuel: un technicien Entretien Pro-Actif vérifie l’étanchéité du conduit, nettoie les parties non accessibles et remplace les filtres à charbon si nécessaire.

Household appliances

Cleaning the inside of the oven and fan

Quarterly

Quick cleaning: every month, or as soon as you notice visible splashes.
Thorough cleaning: every three to six months, depending on how often you use it and the type of food you cook.
Annual professional maintenance: an Entretien Pro-Actif technician performs a complete cleaning, checks the seals for leaks, and verifies that the heating elements are working properly.

Household appliances

Descaling and cleaning the coffee maker

3 to 6 months

Descaling: every 3 months in hard water, every 6 months in soft water
Internal cleaning: after each series of infusions, rinse the filter holder and carafe
Annual professional maintenance: an Entretien Pro-Actif technician performs a complete descaling and checks all parts

Appareils électroménagers

Dépoussiérage de la télévision, console et appareils multimédia

1-3 mois

Dépoussiérage léger: toutes les deux semaines, pour enlever la couche de surface sur l’écran et les boîtiers.
Entretien approfondi: tous les trois mois, incluant l’ouverture partielle des boîtiers (consoles, amplis) pour aspirer les poussières internes.

Household appliances

Microwave oven maintenance

1 to 2 months

Nettoyage intérieur léger: après chaque utilisation qui génère des projections (pop-corn, sauces, plats liquides).
Entretien approfondi: une fois par mois, pour un décrassage complet de l’enceinte, du plateau et des orifices de ventilation.
Inspection professionnelle: tous les deux ans, un technicien Entretien Pro-Actif vérifie l’état des joints, du magnétron et des systèmes de sécurité.

Security

Testing smoke and CO detectors for proper functioning, replacing batteries, and dusting

Monthly tests and annual batteries

Test de fonctionnement: une fois par mois, appuyez sur le bouton « Test » jusqu’au déclenchement de l’alarme.
Remplacement des piles: au moins une fois par an, ou dès le premier signal sonore de piles faibles (bips répétés).
Dépoussiérage: tous les six mois, pour enlever la poussière autour des grilles de détection.
Remplacement complet de l’appareil: tous les 10 ans pour les détecteurs de fumée et tous les 5 à 7 ans pour les détecteurs de CO, selon les préconisations du fabricant.

Security

Functionality test, replacement of batteries in locks and alarm systems

Quarterly to yearly

Full functional test: every three months, simulate arming and triggering, check notifications (audible, SMS, app).
Battery replacement: once a year, or as soon as the device signals a low battery level (beeps or alerts).

Interior structures

Walls and ceilings: inspection for cracks, mold, and minor interior repairs

Twice a year

Visual inspection: twice a year, preferably in spring (after the wet winter) and autumn (before the cold season).
Targeted inspection: after any event likely to cause movement (heavy construction work, structural reinforcement, storms).
Professional intervention: every two years, for a complete audit combining moisture diagnostics and assessment of partition stability.

Structures intérieures

Stairs and railings: stability check, screw fastening, and finishing

Annual

Inspection visuelle et test de stabilité: tous les six mois, pour détecter immédiatement tout jeu ou fissure.
Resserrement et ajustements: une fois par an, examinez chaque fixation et rééquilibrez l’ensemble si nécessaire.
Finition et protection: tous les deux à trois ans, renouvelez la peinture, le vernis ou l’huile de bois pour protéger durablement vos escaliers.

Water softener or water filter

Cleaning, replacement of cartridges

6 months

Vérification mensuelle :
• Contrôlez le niveau de sel du bac de régénération (adoucisseur) et ajoutez-en si nécessaire.
• Vérifiez la pression d’entrée et l’absence de fuites autour du filtre et de l’adoucisseur.
Régénération automatique :
• Programmez la régénération de la résine selon la dureté de votre eau et votre consommation (généralement toutes les 7 à 14 jours).
Remplacement des cartouches :
• Pour un filtre à sédiments ou à charbon actif, changez la cartouche tous les 6 à 12 mois, en fonction de la qualité de l’eau et du volume filtré.
Entretien professionnel annuel :
• Nettoyage en profondeur du bac à sel, rinçage des résines, contrôle des vannes et calibration du programmateur.

FAQs

bottom of page